Documented below are the improvements made with each new firmware version we make available. We remind you that with Ermes updating a firmware remotely is quick and easy, just a click and everything happens automatically.
ErmesLog version 4, 5 & 5s
9.10 – 12/09/2024
- modified readings synchronization: can be activated based on web parameter
- modified display contrast menu: blocked extreme values
- modified shell command: mbw
- apn menu blocked in read-only mode if chip-sim is activated
- periodic check of touch buttons parameters
- fix possible problems in ftp download procedure
- fix possible problems with Aurora protocol (Ermes5s only)
9.8 – 29/08/2024
- PT21A01 temperature sensor
- SHT30 weather probe
- Taosonics flow meter
- DEYE SUN-100K-G03 inverter
- support for bootloader 1.0.3 (Ermes 5s only)
- modified shell command: mew
- fix possible 485 problems on multiple block readings
- fix failed hot start webshell session after a reboot
9.7 – 01/07/2024
- Fix potential connection issues with Chip Sim on Wind networks (only Ermes 5s)
- Fix potential firmware update issues via modem connection (only Ermes 5s)
9.6 – 23/02/2024
- Resolved some modem connection issues on model Ermes 5s
- New integrated pulse counter for inputs 1-4 (Ermes 5s only)
- Solis GC hybrid inverter, BMS, and Meter
- Solis S5 inverter
- HUAWEI LUNA energy storage system
- Elpower Cleanverter
- Fronius SunSpec (Symo, Float setting)
- Pixsys digital inputs
- Zucchetti Hybrid 3-Phase: increased MPPT from 2 to 8
- Sungrow SG33CX/SG40CX/SG50CX/SG110CX: increased MPPT from 8 to 16
- Fixed Kaco Blueplanet 60 TLx inverter modbus issues
- Fixed possible protocol issues with protocol Bonfiglioli on Ermes 5s
- Modified driver for Zucchetti Hybrid 3-Phase inverter
- Various modifications to Chint DTSU 666 meter maps
- Modified HUAWEI SUN2000 KTL 3/4/5/6/8/10/12/17
- Modbus driver for Kostal Piko inverter
9.5 – 23/02/2024
- First version compatible with new model Ermes 5s
- Compatibility with new EG915U modem
- SMA STP 15000TL-30 inverter, Modbus driver
- Control function can be activated for IEC 62056 protocol
- Fixed display reactivation failure after low power mode
- Fixed remote bootloader update procedure (only Ermes 4 and 5)
- Fixed possible problems with Ethernet cable detection
- Fixed flashing red LED not deactivated
- Fixed possible problems with display menu Static IP
9.4 – 17/10/2023
- Fixed compatibility with models equipped with EG25 modem
- Fix possible Ethernet problems on networks with proxies
- Reading time synchronization function
9.3 – 04/10/2023
- Fix possible Ermes5 problems with external SIM cards
- New IME ACCOUNT D4 counter
- New CAREL weather station
- New driver for Kaco Blueplanet 60 TX1/TX3 inverter with Modbus protocol
- Adding temperature to Zucchetti ZCS Azzurro 1-40 kW (2 MPPT)
- Temperature added to Santerno Sunway TG
- Modified Zucchetti Hybrid 1-Phase battery driver
- Modified Zucchetti Hybrid 3-Phase battery driver
- Modified Goodwe MT inverter driver
9.2 – 08/08/2023
- Fix some DNS problems since 9.0
- Added temperature to Huawei
- SUN2000 100 KTL inverter
- Added temperature to ZCS hybrid 3-Phase inverter
- New driver: SIEL_SOLEIL_HYBRID
- New driver: BMS SIEL_SOLEIL_HYBRID
9.1 – 10/03/2023
- Fast boot without reboot on first install
- Quick start without reboot after remote configuration update
- Possibility to stop reading slaves with ctrl-c
- New Telit modem driver (Ermes 4 only)
- Chint counter DTSU 666
- GoodWe HT and MT series inverters
- Seneca Z-5DI-2DO pulse counter (inputs 1 and 2)
- Seneca Z-10-D-IN pulse counter (inputs 9 and 10)
- String-box PhoenixContact Solar check
9.00 – 15/11/2022
- digital input SIEL SPS 6600
- string-box Kernel Sistemi ST0HS 0825 e 1225
- temperature probe MD02
- BMS Zucchetti Hybrid 1-Phase
- BMS Zucchetti Hybrid 3-Phase
- inverter Zucchetti Azzurro 3-Phase 100 KTL
- stack update FNet 4.7.1
- fix some 4G modem problems during first power up and after sim change
- ability to type custom APN from shell
8.10 – 22/06/2022
- Reset command from display
- Fix possible errors with setting parity “e” in Modbus protocol
- Refurbished shell info command
- Fix ISOIL_ML311
- FAUN flowmeter
- Three-phase ErmesMeter
- ABB_DMTME_M2M
- Gateway AZUR_DLMS_1
- Azur Energia GW-DLMS-232-EMH
- SMA inverter STP110-60 CORE2
- GROWATT_TLX inverter
8.9 – 29/01/2022
-
New driver: Fimer / ABB single-phase inverter, CONTREL_EML16_V2, HUAWEI_KTL_36_M3
-
New shell command: mew (modbus ethernet write)
-
Fixed some 4G modem problems with some types of SIM in roaming
8.7 – 22/11/2021
- Sim chip enabling function from display
- New drivers: Caleffi Code, Qeed QI-50
8.6 – 18/11/2021
- New driver: Huawei SUN2000 from 3 to 12 KTL
8.5 – 03/08/2021
- Predisposition for 4G modem with pre-assembled sim-on-chip
- Support of Bootloader 2.0.7
- Fixes possible problems on first boot after a prolonged shutdown period
- Fixed problems with some types of probes connected to terminals T1, T2 and PIR
8.4 – 26/07/2021
- Fixed ethernet problems with some types of switches
- Fix APN shared.tids.tim.it
- New drivers added:
- FRER_NANO_IV
-
PVS_50_TL_S, SIEL_BMS
-
SIEL_EMS_METER
-
ATON_IV
-
ATON_BATT
-
ATON_METER
-
ABB_VSN800
-
ISOIL_MV311
-
RIELLO
-
SANTERNO_METEO
-
XY-MD02
8.3 – 26/05/2021
- support of bootloader 2.0.6
- Fix driver Zucchetti Hybrid 1-phase
- add APN resiot.m2m automatic
- Fix possible problem with APN inetd.it.vodafone.iot
- Possibility of operation without 4G module
8.2 – 28/04/2021
- Support for new external flash memory
- Replaced SD command with storage command
- Fixed some data sending problems after using USB Shell
- Fix possible problems with APN inetd.it.vodafone.iot
- Fixed some device reading problems through Modbus-TCP protocol
- Fixed some modem boot problems on Ermes5
8.1 – 18/03/2021
- First firmware version compatible with both the ErmesLog 4 and ErmesLog 5 series
- New: menu for adjusting the display contrast
- New drivers: SIEL_SPX_3F
- Fix driver: SIEL_SRT_3F, SIEL_SRT_1F, PVS_100, FRONIUS_PRIMO
- Fix compatibility issues with some types of SD cards
- Fix “<-stop” command from display during “task s” and “scan all devices”
8.00 – 01/03/2021 – (solo ErmesLog 5)
- first firmware version of the new ErmesLog 5
- support display, touch buttons, 4G modem
- Autoconnect: automatic net connection management, preferred net
- Shell: pause task while typing keyboard
- SD card sector failover during download (prevents errors in case the SD card is damaged)
- new driver for SIEL: ID_SIEL_SRT_1F
- new driver for SOCOMEC: ID_SOCOMEC_IFB_12
7.60 (only ErmesLog 4)
- ABB PVS-50
ABB PVS-100 String Combiner
SIEL SRT 3F
Zucchetti ZCS Storage single-phase
Fronius current and DC voltage fix
7.57
- SMA HighPower
- Inverter Kaco
- Easy-4-Hall
- Led panel Brollo
- UPS Safepower S PF1 3L
- UPS Safepower SPM PF1 3L
7.56
- UPS Safepower S PF1 2L
7.54
- Parameter backup on SD card
7.53
- Webshell
7.52
- Fix 485 reads problem in case of noise UART error
- Added UART warning at the end of the read command
7.51
- ET Flow Sensor
- Mars 810 230 panel dirt sensor
- Inverter and EEI String-Box
- SolarEdge
- Heinrichs Messtechnik Vortex Oil
- Zucchetti 50000
7.49
- ABB PVS 100
- JEMA IF-100
- Huawei SUN2000 60-KTL
- Seneca Z-4RTD2 (I PT-100)
- APN iot.windtre
7.48
- Fixed bug that sometimes blocked the delivery of readings
7.46
- Marcom GW-IMP-WEB-1-S
- Pin on SIM FG
7.44
- Marcom GW-IMP-WEB-1-S
7.43
- Santerno TG (register with higher resolution for total energy)
- Circutor TR8
7.41
- BTicino F4N200 (electricity meter)
- Proline T-Mass 65 (gas meter)
7.40
- Modbus temperature sensor
7.38
- Tecnint EMS SAV 8 (string-box)
Electrex Femto Net (electricity meter)
7.37
- Gavazzi EOS Array (string-box)
Zucchetti ZCS (inverter)
Contrel EMI (flow meter)
7.36
- OnBoard Digital-Input reading every 30 seconds
- Sontex Supercal (flow meter)
- Seneca ZC-24DI (digital-input)
7.34
- Sofar Solar (inverter)
- ISOIL ML-311 (flowmeter)
- Ermes Ghost (energy meter)
- Circutor CVM-MINI (network analyzer for inverters)
7.33
- Omron KP100L (3 MPTT)
- Solarmax 35C
- Ingeteam String Control
- Ecostring
7.32
- ISKRA MT880
- Sungrow KTL
- IME CE4DMID01
7.30
- Apn for FastWeb
- BM Green Power String-Box ASI and Solarimeter
7.29
- Contrel EMU network analyzer (subset of registers to measure generic inverter)
7.28
- UPS SIEL SAFEPOWER SPM
7.27
- Meter Contrel EMU
- Inverter Growatt
- Inverter HUAWEI SUN2000 KTL
7.23
- Danfoss solarimeter
- SIEL UPS HF: bit 28 is considered alarm when it is 0
7.22
- Heap size increased from 2kB to 4Kb
- Solarimeter Ingenieurbüro Si-RS485
- SIEL UPS HF: bit 5 is no longer considered alarm when it is 0
7.21
- Inverter Aurus
- INEPRO 380
- Weidmüller Transclinic 8i+ e 14i+
7.20
- The maximum number of readings sent for each communication with the web-server has been increased to 12
- Fix not saving Flash readings in case of GPRS error
- Fix not saving DNS from command line
- AROS String-Box Analog Input (solar meter)
- IFX-F100
- Schneider PM9C
- Custom layout for Siemens WR1 + WR2 adapter and for LSI E-Log with humidity sensor and three pyranometers
7.19
- ABB B21 / B23 / B24
- SUNSIEL with energy register
- SMA Modbus SunSpec Profile
7.18
- New Vodafone APN (mobile.vodafone.it)
- APN Greek operators (Cosmote, Vodafone, Wind, Q-mobile)
- Cabur E-Box
- Seneca Z-D-OUT
7.17
- Fixed SIEL SunSiel alarm logs
- Seneca Z4-AI (temperature probes)
- Cabur E-Box
7.16
- Energy Team X-Meter (pulse counter)
- Inserted a pause of 350 ms. between the first and second message in the IEC 62056-21 driver for Itrons
7.14
- ABB ANR
7.13
- Lovato DMG-110
- ABB M2MDMTME
- ABB DMTME
7.12
- Inserted a pause of 100 ms. between the first and second message in the IEC 62056-21 driver for Itrons
7.11
- Commands to customize the ftp server and the central server
7.10
- Selco STL and TTL from modbus card SI20 (cod. E9.00.001)
- USB stack (beta)
7.9
- Contrel EMT-AS
- Command to disable all tasks
7.8
- Increased to 2 sec. the timeout of the modbus over ethernet response
StringComb Power-One
7.7
- Reference boot loader version increased to 2.0.4
- Energy Team X-Meter (pulse counter)
7.6
- Increased to 3 sec. the timeout of the modbus rtu response
- Return to 1 sec. the reading pause between two devices
- IBLE information panels
- Reading of alarms and status of SIEL UPS every 30 seconds
7.5
- Increased to 1.5 sec. the timeout of the modbus response
Remote boot-loader update
7.4
- Fix modbus reading error on different blocks of the same device (eg. Gavazzi EM24 / EM26)
7.3
- Telnet access
- Unique MAC
- Seneca Z-8AI (string-box)
- Seneca Z-4AI (temperature probes)
- Seneca ZC-24DI (digital-input)
- Itron T-mod (2)
- Marcom Gateway DLMS-Modbus for Landis-Gyr (I and II meter)
- Increased reading pause between devices to 2 seconds
- Increased attempts to read a device from 3 to 5
- Command “pause” to temporarily change the reading pause
7.2
- Support for 50 devices
7.1
- First release. It supports all drivers up to ErmesLog 3 – 6.8
ErmesLog 3 (end of support)
6.44 – 25/10/2021
Latest update. Product out of support.
- SUN2000-nKTL-M0 (with n = 3,4,5,6,8,10,12)
- Modified driver: Riello
- APNs added: inetd.it.vodafone.iot, shared.tids.tim.it, iot.1nce.net, iliad, RESIOT.m2m
6.43 – 17/06/2021
- New driver:
- CONEXT_CL25E
- HUAWEI_SUN2000_100_KTL
- KERNEL_ST2
- SOCOMEC_IFB_12
- ATON inverter, battery, meter
- SANTERNO_METEO
- ABB_VSN800
- ISOIL_MV311
- RIELLO
- FRER_NANO inverter
- ABB PVS_50_TL_S
- SIEL BMS
- EMS Meter 1-4
6.42 – 12/04/2021
- Fixed some firmware download issues via http
6.41 – 07/04/2021
- Fixed some Iskra meter reading problems
6.40 – 01/03/2021
- Fixed some firmware download problems via ethernet on versions from 6.36 to 6.39
- Fixed some problems on port 485 when using IEC protocol on versions from 6.36 to 6.39
6.39*, 6.38*, 6.37*
- Fix problem reading 485, 422 and 232 in case of noise UART error
6.36*
- SMA Highpower
- Weidmuller 16
- Sungrow 110CX
- Sunguard Sensor-Box
- UPS Safepower S PF1 2L
- UPS Safepower S PF1 3L
- UPS Safepower SPM PF1 3L
6.35
- ET Flow Sensor
- Seneca Z4 RTD2
- MARS 810230
6.34
- Webshell
- APN inetd.it.vodafone.iot
6.33
- APN iot.windtre
6.32
- Pin on Fractalgarden SIM
6.31
- Solarmax 35C
6.30
- Apn for FastWeb
- BM Green Power String-Box ASI
- Inverter Growatt
- Inverter HUAWEI SUN2000 KTL
- Ingenieurbüro Si-RS485
- Solarimetro Danfoss
- Inverter Aurus
- INEPRO 380
- Weidmüller Tranclinic 8i+ e 14i+
6.29
- Schneider PM9C
- IFX-F100
6.26
- ABB B21/B23/B24
- SUNSIEL con energy registry
- SMA Modbus SunSpec Profile per STP nn000TL-10
6.25
- SMA Modbus SunSpec Profile per STP nn000TL-30
- Seneca Z-D-IN (gas meter)
6.24
- New Vodafone APN (mobile.vodafone.it)
- APN Greek operators (Cosmote, Vodafone, Wind, Q-mobile)
- Cabur E-Box
- Seneca Z-D-OUT
6.23
- Fixed SIEL SunSiel alarm logs
- Seneca Z-4-AI (temperature probes)
6.22
- Energy Team X-Meter (pulse counter)
- Inserted a pause of 350 ms. between the first and second message in the IEC 62056-21 driver for Itrons
6.20
- ABB ANR
6.19
- Lovato DMG-110
- ABB M2MDMTME
- ABB DMTME
6.18
- Inserted a pause of 100 ms. between the first and second message in the IEC 62056-21 driver for Itrons
6.17
- Increased to 2 sec. the timeout of the modbus over ethernet response
Selco inverter power calculation fix
6.16
- StringComb Power-One
6.15
- Lettura Selco STL e TTL da scheda modbus SI20 (cod. E9.00.001)
6.13
- Reading of alarms and status of SIEL UPS every 30 seconds
- IBLE information panels
6.12
- Lowered to 1 sec. the reading pause between devices
- Seneca S203RC-D
6.11
- Increased to 3 sec. the timeout of the modbus response
6.10
- Increased to 2 sec. the reading pause between devices
- Increased attempts to read a device from 3 to 5
- Command “pause” to temporarily change the reading pause
6.9
- Seneca Z-8AI (string-box)
- Seneca Z-4AI (temperature probes)
- Seneca ZC-24DI (digital-input)
- Itron T-mod (2)
- Marcom Gateway DLMS-Modbus for Landis-Gyr (I and II meter)
- Unique MAC
6.8
- Inverter HUAWEI
6.6
- Fix SIEL weather station logs
6.5
- Minor version of the two-digit firmware
6.4
- Ducati LCD e LCD95 (bidirectional)
- Seneca S5xx
6.3
- Socomec Countis (III INPUT)
6.2
- SIEL SunSIEL
6.0
- Seneca S6xx
- Socomec COUNTIS
- Socomec SUNSYS PRO
- SIEL digital-input card
5.9
- Marcom Gateway DLMS-Modbus 1 per Landis-Gyr (I meter)
5.8
- SMA Sunny Sensorbox
- Siemens Sentron PM4200
- Deleted default server from configuration. A new data-logger now always asks the control panel what the target server is.
5.7
- SIEL Analog Inverters (Siel Solar Converter)
- Fimer R400 / R800 / R5000 inverter
5.6
- Ducati Energia meters
5.5
- Socomec
- Tecnint EMS SAU
5.4
- Samil Solar-Lake
- Energy-Team String-Box
- IME CONTO IMP (ingressi 7, 8, 9)
- Gavazzi whether station
5.3
- Seneca Z-D-IN
- Gavazzi EM 24/26
- Siel UPS HF
- Siel Soleil TL
- Siel PV-String-Box 12
- Omron KP100L
- IME CONTO IMP
- Turck
- Siliken JB
5.2
- Itron counters on IEC-62056
- Siel UPS EVO
- Socomec Diris A60
- Bonfiglioli inverter
- String-Box Tecnint EMS
- Shipping of the DNS to the platform
5.1
- Map modbus registers to read Schneider PM3200 as if it were an inverter
- IP forwarding, netmask and gateway even when the data-logger uses the SIM
5.0
- String Inverter Gefran
- String-box Gefran
4.9
- Uniconfort boilers
- Fixed Samil River inverter register map
- Added retry mechanism to yasdi driver (SMA) broadcasts
- Eliminated console modem. Any communication output via modem or ethernet is shown in the main console (the only one)
- The time interval beyond which the data-logger restarts if it fails to communicate with the platform has been raised from 15 to 20 minutes
4.8
- Extended map of Seneca counter registers
- Procedure for setting the 4-noks and Contrel relays (not yet remotely activated)
- Bugfix: led L1 remained on in energy saving mode with only one device present
4.6
- Contrel AC/DC TRMS
- FRER meter
- Astrid Array-Monitor whether sensors
- SolarMax MT
4.5
- Contrel EMM-µD3 extended register map
- Bugfix Danfoss and Seneca Z-Power driver
- Driver for SMA SC-100
- Viessmann Ecotronic
4.4
- Schneider PM3200
- E.S.A.M.
- Provider Turkcell and Vodafone-ro
- Lock APN to disable provider autodetect
4.3
- Seneca Z-Power e Seneca Z-4AI
- Contrel EMM-D4hp
4.2
- Gefran
- SolarMax (MaxComm protocol)
- REFUsol (USS protocol)
4.1
- Command to operate relays and open collectors remotely
4.0
- Modbus driver to monitor inverters via Contrel
- SunGuard string-box
- GPRS led off in energy saving mode
3.9
- New FNET
- Ping command
- Samil SolarRiver-D
- Increased the polling frequency of the read database to 20 seconds
3.8
- Increased from 100 to 500ms. the timeout between readings of different devices.
3.7
- SMA with DM-485-CB-10 board
- Sunmeter Solar Solution
- Noverca sim support
3.6
- Easy-4-Hall string-box
- GSL-IT-DA weather station
- Integrated pulse counter
- Energy saving mode
- Reboot if the button is pressed for 3 seconds
- Configuration reset if the key is pressed for more than 7 seconds
3.5
- Helios inverter
- Contrel
- Itron with T-Mod
- User configurable DNS server (default 8.8.8.8)
- If in DHCP, the DNS server is obtained from the server (previous releases always used the default)
- Telnet
3.4
- SUNGUARD SG-METER
- Firmware download from HTTP if connectivity is over Ethernet
- Support for remote opening and closing of the Open Collector door
- Command to show / set the status of the photo coupled input
- Command to show / set the relay status
- Command to show / set the status of the open collector door
3.3
- ANSWER Solargate
- ANSWER String-Box
- 4-Noks ZR_PLUG e ZR_METER
3.2
- Sunway MX S: corrected alarm log
- Astrid Array-Monitor
- Removed reading of the slaves 2 minutes after boot
3.1
- DHCP
- String-box Righini
3.0
- Increased timeout for receiving modbus messages (from 500 to 700 ms)
- New version of the configuration
- The “server” command only saves servers included in a wired list
- New type of device for solar thermal
2.9
- Increased some modem send and receive timeouts
2.8
- Fixed bug that blocked the sending of ADC data once data was written to flash
2.7
- Print RSSI (received signal strength indication) and Bit Error Rate of the modem
- DPEE
- Transmitting of digital input status
- Fixed YASDI driver (SMA) bug that prevented reading of some Sunny Mini Centrals.
2.6
- Data transmission method via ethernet (and relative command to set it)
- ABB CS0 5000
- Clearing the contents of the flash after a configuration update
2.5
- Fixed a bug in 2.4 that prevents the sending of readings saved in RAM in the data-loggers with the ADC as the only device
2.4
- Send multiple readings in one message (maximum 6 at a time)
- Reduced the reboot threshold from 1 hour to 15 minutes due to lack of communication with the web-server
- First implementation of the driver for Kostal Piko (to be verified in the field)
- The maximum number of devices that can be stored is set at 30 + the ADC
2.3
- Flash saving of readings before a reboot or in case the 100 RAM slots are filled (the flash can hold 23000 readings)
- Dispatch of readings saved on flash (one every ~ 20 seconds, starting with the most recent)
- Firmware version shipping
- Fronius driver: AC voltage reading
- Removed the “save” command. Any command line changes are automatically saved
2.2
- Saving in memory of the readings in case of no communication with the web-server (max. 100 readings).
- Dispatch of readings every ~ 10 seconds, starting with the most recent.
- Power-One and Aurora protocol: energy reading of Aurora Central and AC current and voltage of single-phase.
- Icarus
- LSI Lastem Sensor-Box
- Shipping apn
- Fix buffer overflow in iccid shipment
- Fix adc initialization after firmware update
2.1
- Improved quality of data read by ADCs (10 second sampling)
Shipping iccid
* Do not use these releases. They contain a bug that can prevent communication with certain classes of devices